Reduces startup impact and noise: The Water Pump Motor Soft Starter with Bypass Inside gradually provides startup voltage for water pump motors, preventing excessive current and reducing impact and noise during startup, protecting mechanical equipment and the power grid.
Water Pump Motor Soft Starter with Bypass Inside
- Reduces startup impact and noise: The soft starter gradually provides startup voltage for water pump motors, preventing excessive current and reducing impact and noise during startup, protecting mechanical equipment and the power grid.
- Lowers failure rate: Using a water pump motor soft starter can significantly prolong the lifespan of equipment and reduce failure rates.
- Ensures smooth startup process: The soft starter ensures a smooth and gradual power supply during startup, allowing ample time for preparation before the motor starts.
- Saves energy during startup: The water pump motor soft starter reduces energy consumption by minimizing the need for large capacity air switches and electrical elements.
- Features bypass inside: This soft starter is equipped with a bypass function, allowing for convenient operation and maintenance.
Main Menu |
Sub Menu |
Parameter |
A. S&P Para |
A00.Curr Limit for CLS |
10%~500% |
A01.Init Volt for VRS |
30%~80% |
|
A02.Start Time for VRS |
1~120s |
|
A03.Volt for Plus Start |
30%~80% |
|
A04.Time for Plus Start |
0~500ms |
|
A05.Curr Limit for CRS |
10%~400% |
|
A06.Start Time for CRS |
1~120s |
|
A07.Volt for Jog |
30%~80% |
|
A08.Time for Soft Stop |
1~10s |
|
A09.Start Mode |
Volt Ramp Curr Limit Jog Curr Ramp Plus & Ramp C-Limit Ramp |
|
A10.Stop Mode |
Free Stop Soft Stop |
|
A11.Control Mode |
Forbid Key Board Terminal Ctrl Term & Key |
|
A12.Prog Relay Func |
Non-Func Power On Standby Starting Bypass Stopping Running Fault |
|
B.Protect |
B00.Start OC Ratio |
400%~600% |
B01.Running OC Ratio |
200%~400% |
|
B02.Start OL Level |
1~8 |
|
B03.Running OL Level |
1~8 |
|
B04.Curr Unbalance Ratio |
5%~85% |
|
B05.Over Volt Threshold |
100%~140% |
|
B06.Under Volt Threshold |
60%~100% |
|
B07.Under Load Threshold |
0%~100% |
|
B08.Under Load Delay |
0~200s |
|
C.Run Para |
C00.Starter Rated Curr |
Factory Constant |
C01.Starter Rated Volt |
Factory Constant |
|
C02.Motor Rated Curr |
5A~Starter Rated Curr |
|
C03.Curr Cali Ratio |
50~1500 |
|
C04.Pulse Under Running |
Pulse No Pulse |
|
D. Misc |
D00.MODBUS Addr |
1~127 |
D01.Baud Rate |
19200 9600 4800 2400 1200 |
|
D02.Volt Cali Ratio |
5~200 |
|
D04.Language |
Chinese English Russian |